In an emergency, an eCall system must transmit the information needed to support an emergency response.

But how can automotive manufacturers ensure that the data transmitted by an in-vehicle emergency system remains within the defined scope?

For OEMs, Tier 1 suppliers and eCall system developers, data content and transmission logic deserve careful attention during system validation.

1. Regulatory Background: Regulation (EU) 2015/758

Regulation (EU) 2015/758 establishes type-approval requirements for the deployment of the 112-based eCall in-vehicle system.

Article 6 addresses privacy and data protection.

In particular, Article 6(8) states that the Minimum Set of Data (MSD) sent by the 112-based eCall system should contain only the minimum information referred to in the cited EN 15722:2011 standard, and that no additional data should be transmitted by the 112-based eCall system.

The same provision also addresses the storage and permanent deletion of MSD data.

2. What Should Automotive Developers Pay Attention To?

A. Data Content

The MSD is not intended to become a general-purpose vehicle data package.

Development teams should review:

  • The data fields included in the MSD

  • The source of each data item

  • The mapping between vehicle information and the applicable MSD definition

  • Whether any additional information is being included in the 112-based eCall transmission

B. Data Transmission

The transmission process should be reviewed against the intended emergency-call workflow.

Relevant project checks may include:

  • Whether transmission is triggered under the intended emergency conditions

  • Whether the correct MSD content is generated

  • Whether the transmitted data matches the prepared data

  • Whether unexpected or additional fields appear in the transmission

C. Data Storage and Deletion

Article 6 also addresses data retention and deletion.

Engineering teams should review:

  • How MSD information is temporarily stored

  • How data is removed when it is no longer required

  • Whether the system supports full and permanent deletion

  • Whether data is accessible outside the 112-based eCall system before an eCall is triggered

3. What About TPS eCall and Other Connected Services?

An important distinction is necessary.

The requirements discussed above concern the 112-based eCall in-vehicle system. They should not automatically be interpreted as a blanket prohibition on all data processing by every connected vehicle service.

Article 6 separately addresses TPS eCall and other added-value services.

It also requires appropriate separation between the 112-based eCall system and additional systems providing TPS eCall or added-value services, including restrictions on the exchange of personal data between them.

This distinction should be reflected in the system architecture and compliance assessment.

4. A Practical eCall Validation Checklist

For project teams, the following checks can help organise validation activities:

Data definition

  • Review the applicable MSD specification and version.

  • Map each transmitted data field to its technical definition.

  • Identify any additional fields in the transmission structure.

Transmission behaviour

  • Verify the data generated during the intended emergency-call scenario.

  • Compare the prepared MSD with the transmitted content.

  • Review abnormal and interrupted transmission scenarios.

Data protection

  • Review data access before eCall activation.

  • Examine data storage and deletion mechanisms.

  • Assess separation between the 112-based eCall and additional service systems.

These are project validation recommendations. The specific test procedures should be determined using the applicable technical and type-approval requirements.

5. An Important Note on Standard References

The consolidated text supplied for this review is dated 9 May 2024.

It is important to distinguish Article 6(8), which refers to EN 15722:2011, from Article 5(8)(d), which lists EN 15722:2020 in its technical standards section.

Project teams should verify the applicable legal text, standard edition and relevant implementing requirements before finalising a compliance assessment.

Final Thoughts

eCall compliance is not only about establishing an emergency call. The accuracy of data content, transmission behaviour, storage and privacy protection are also important parts of the overall system assessment.

At Blue Asia, we support automotive electronics projects through EMC testing, wireless certification and automotive-related testing and compliance services.

For teams developing in-vehicle communication and connected automotive systems, we welcome discussions on potential testing and certification cooperation.


Contact: [email protected] | WhatsApp: +86 17663606879


SHARE

本文作者

Olivia

CNAS 認可實驗室工程師,分享射頻、EMC 與全球認證一線筆記。

獲取報價

在線服務

[email protected] 4000259520 8613534225140
首頁 熱線電話 手機號碼 電子郵箱
回到頂部
聯繫我們
我們使用 Cookie 以提升您的線上體驗。繼續瀏覽本網站,即表示您同意我們使用 Cookie。

Cookies

關於 Cookie

Cookie 是瀏覽網站時儲存在您裝置上的小型文字檔案。藍亞實驗室使用 Cookie 記住您的語言偏好、保障表單安全,並瞭解訪客如何使用我們的頁面。

我們使用的 Cookie

必要 Cookie——語言選擇與表單安全,無法停用。
效能 Cookie——用於改善網站的匿名流量統計。

我們不使用廣告或追蹤 Cookie。您可以隨時在瀏覽器設定中封鎖或刪除 Cookie,但部分功能可能受到影響。

聯絡我們

對本政策有任何疑問?請傳送電子郵件至 [email protected]。